A free process control resource from Wastewater Solutions, Inc.help@ActivatedSludge.com  |  503-701-2766
ActivatedSludge.comPractical wastewater process control

Calculators

Process control math with US and metric units, formulas and worked examples.

FEATURED TOOL

State Point Clarifier and RAS Control Tool

Plot the solids flux curve, overflow and underflow lines from settling tests or SVI, see whether your clarifiers are underloaded, critical or overloaded, and get a suggested RAS range.

Process control

Clarifiers

Loading

Aeration

Chemistry

Hydraulics

Lab

Solids

Instruments and Controls

4-20 mA Signal Converter

Most plant transmitters send a 4 to 20 mA signal where 4 mA is the bottom of the range (LRV) and 20 mA is the top (URV). Use this to check what the PLC or SCADA should show for a current you measure, or what current to expect for a process value. It also flags currents that NAMUR NE43 treats as a failure.

Instrument Accuracy and Calibration Check

An accuracy spec means very different things depending on whether it is a percent of span, of reading, or of the sensor upper limit. The first tool shows the real error band at the reading you care about. The second records a 5-point check (0, 25, 50, 75 and 100% of range) and grades the as-found and as-left results against your tolerance.

Flume and Weir Flow Calculator

Open channel flow meters measure head and convert it to flow with a fixed equation for the primary device. Use this to check the flow your level transmitter or flow meter shows, or to build a check table. US units: head in feet, flow in cubic feet per second, gpm and MGD. The equation used and its valid range are shown with each result.

Mag Meter Velocity Calculator

A mag meter measures velocity and multiplies by the pipe area. Too slow and accuracy suffers and coatings build up; too fast and you get head loss and wear. Check the velocity at your normal and minimum flows, or find the size that gives a target velocity.

Tank Level, Volume and Hydrostatic Pressure

Chemical, sludge and wet well levels are often measured as pressure and then shown as a level or volume. The first tool turns a level into gallons for common tank shapes. The second turns a pressure reading into a level, corrected for specific gravity and the sensor mounting height.

Pressure Unit Converter

Gauges, transmitters and pump curves use different pressure units. Enter a value once and see it in every common unit, including inches of water at both 39.2 °F and 68 °F, since transmitters differ.

Pump Affinity Laws and VFD Speed

When a VFD slows a centrifugal pump, flow drops with speed, head with speed squared and power with speed cubed. That is why VFDs save energy. It is also why a pump slowed too far cannot lift against static head and just churns.

Three-Phase Motor Power Calculator

Clamp-on amps and a voltage reading tell you a lot about a motor. Use these to estimate real power, shaft horsepower and yearly energy cost, or to estimate the current a motor of a given size should draw.

DO Saturation and Sensor Check

A DO analyzer is calibrated against the oxygen that water can hold at saturation, which falls with temperature and elevation. This finds the saturation value for your conditions, shows a reading as percent saturation, and compares an online analyzer with a Winkler or calibrated handheld reading.

pH Electrode Slope and Buffer Calculator

A pH electrode makes about 59 mV per pH unit at 25 °C, less when cold and more when warm. A healthy electrode is close to that ideal. Use these tools to correct buffer values for temperature, grade a two-point calibration by its slope and offset, and see the theoretical slope at your sample temperature.

Every calculator runs in your browser, switches between US and metric units where it makes sense, shows the formula, and loads a worked example from the fictional White River WRRF. Nothing you enter is sent anywhere.