1Symptom
The 30 minute settled volume (SSV30) is high and the sludge volume index (SVI) has climbed above about 150 mL/g, or it has risen 30 to 50 points over a week or two. Clarifier blankets run deeper than normal, and at high flow you may start to see solids carry over the weirs.
2Check first
- Run the settleometer yourself today. Read SSV at 5, 10, 15, 20 and 30 minutes and look at the supernatant: clear, cloudy, or full of straggler floc.
- Confirm the MLSS used in the SVI is from the same sample and time. A bad MLSS number makes a bad SVI.
- If SSV30 is above about 800 mL/L, repeat with a 1:1 dilution (diluted SVI). An undiluted test in a crowded cylinder overstates SVI.
- Put a drop under the microscope at 100x. Are there filaments extending from the floc and bridging between flocs, or is the floc itself loose and spread out?
- Measure the blanket in every clarifier and note which ones are deepest.
3Possible causes
- Filamentous bulking: low DO, low F/M, nutrient deficiency, septic influent or high grease feed favor filaments.
- Viscous (non-filamentous, zoogloeal) bulking: too much slime, often from nutrient deficiency or high F/M with readily degradable food.
- Low DO for several days, for example from a blower outage. At White River WRRF the SVI rose from about 115 to 150 in a week with one blower out.
- Septic or high sulfide influent, or septage and hauled waste dumps.
- Sudden SRT change, or an F/M that swings widely between weekday and weekend loads.
- Low pH or a toxic event that damaged floc formers more than filaments.
4Next investigation
- Trend SVI, MLSS, F/M, SRT, DO by zone and temperature for the last 30 days on one chart.
- Do a filament ID: Gram and Neisser stains, filament abundance (0 to 6 scale), and dominant type.
- Check nutrients in the aeration effluent: aim for at least about 1 mg/L ammonia-N and 0.5 mg/L orthophosphate.
- Check influent for septicity (sulfide, low ORP, black color, odor) and review hauled waste logs.
5Corrective actions
- Protect the clarifiers first: run the state point tool and adjust RAS so the underflow line clears the flux curve.
- Fix the cause the microscope points to: raise DO in the first zone, correct nutrients, stop or meter septage, or add a selector.
- Hold SRT steady. Do not make large wasting swings to "fix" SVI. Changes of 10 to 15% per day are plenty.
- If clarifiers are about to lose solids, consider targeted RAS chlorination (see the filamentous bulking guide) as a short term tool, not a cure.
- Keep effluent TSS in check with more clarifier area in service if available.
6When to call for help
- Effluent TSS is approaching a permit limit and blankets are still rising after RAS changes.
- SVI is above 250 mL/g, or you are considering RAS chlorination for the first time.
- You cannot identify the filament type and the cause is not obvious.
Make one change at a time, record it, and follow your plant procedures and permit. If you suspect a toxic discharge, a safety hazard or a permit violation, notify your supervisor right away.