RAS: return activated sludge
RAS pumps draw settled sludge from the clarifier floor and send it to the head of the aeration basin (or the anoxic or anaerobic zone in BNR plants). Typical RAS rates are 40 to 75% of influent flow; White River designs for 50% (4.0 MGD at 8.0 MGD) with five 2 MGD pumps (four duty, one standby), flow paced to influent.
Four ways to estimate RAS:
- Mass balance: RAS = Q x MLSS / (RAS TSS minus MLSS)
- Settleometer: RAS ratio = SSV30 / (1,000 minus SSV30)
- SVI: estimated RAS TSS = 1,000,000 / SVI, then mass balance
- Blanket depth: adjust to hold the target blanket
See How Much RAS Should I Return? for worked examples.
WAS: waste activated sludge
WAS removes the daily growth of biomass and sets SRT. It is usually drawn from the RAS line (thick) or directly from mixed liquor (thin but steady).
WAS (lb/d) = inventory (lb) / target SRT minus effluent solids (lb/d)
WAS (gpd) = WAS (lb/d) / (WAS TSS x 8.34) x 1,000,000
White River design: 90,072 lb / 11.6 d minus 534 lb/d = 7,231 lb/d. At 9,000 mg/L, about 96,000 gpd.
WAS goes to thickening (White River uses gravity belt thickeners), then digestion and dewatering. See Solids Handling.
Mass balance check
At steady state:
Solids into clarifier = solids out in RAS + WAS + effluent
(Q + R) x MLSS = R x RAS TSS + WAS + effluent solids (all in lb/d)
If this does not close within about 10 to 15%, check flow meters and sampling.
Daily routine
- Measure blanket depth in each clarifier.
- Run settleometer and SVI.
- Check RAS TSS and MLSS.
- Compare RAS rate with the four methods.
- Calculate WAS from the SRT target.
- Record changes and reasons.