A free process control resource from Wastewater Solutions, Inc.help@ActivatedSludge.com  |  503-701-2766
ActivatedSludge.comPractical wastewater process control

RAS Problems

Thin RAS, plugged lines, uneven pump flows or flow meter errors.

1Symptom

RAS concentration is lower or higher than expected, blankets differ between clarifiers, or RAS flow readings do not match pump performance.

2Check first

  1. Grab RAS samples from each clarifier and test TSS.
  2. Verify RAS flow meters against pump curves or a drawdown test.
  3. Check for plugged suction headers, rags, or air binding.
  4. Look for a solids mass balance mismatch: Q x MLSS should roughly equal RAS x (RAS TSS minus MLSS) at steady state.

3Possible causes

  • RAS rate too high: thin RAS and high clarifier underflow loading.
  • RAS rate too low: deep blanket, thick RAS, septic sludge.
  • Plugged suction or collector arm.
  • Meter calibration drift.
  • One pump much weaker than others.

4Next investigation

  • Calculate the RAS ratio needed from settleometer, SVI and mass balance methods.
  • Do a clarifier mass balance.

5Corrective actions

  1. Set RAS from the mass balance or state point, then fine tune using blanket depth.
  2. Clear plugs and repair pumps.
  3. Calibrate meters.
  4. Balance RAS per clarifier.

6When to call for help

  • A collector or suction header needs a drain-down.
  • Mass balance cannot be closed.
Make one change at a time, record it, and follow your plant procedures and permit. If you suspect a toxic discharge, a safety hazard or a permit violation, notify your supervisor right away.