SVI Calculator

SVI is the volume in mL occupied by 1 gram of mixed liquor after 30 minutes of settling. 80 to 150 mL/g is typical; above 150 means slow settling.

SVI

Formula

SVI, mL/g = (SSV30, mL/L x 1,000) / MLSS, mg/L
SDI, g/mL = 100 / SVI
Inputs used
  • 30 minute settled volume (SSV30) (mL/L)
  • MLSS (mg/L)
  • Dilution factor (1 if undiluted)

Worked example (White River WRRF, fictional)

  1. SVI = 310 x 1,000 / 2,620 = 118 mL/g

Tips

  • Use MLSS from the same sample as the settleometer.
  • If SSV30 is above about 800 mL/L, dilute 1:1 and enter a dilution factor of 2.