1Symptom
SVI is high (often above 150 to 200 mL/g) and the settleometer shows a loose, fluffy sludge that compacts slowly with a clear supernatant. Under the microscope, filaments extend from flocs and bridge between them.
2Check first
- Rate filament abundance on a 0 to 6 scale at 100x. Abundance of 4 (very common) or more usually affects settling.
- Do Gram and Neisser stains to narrow the filament type (for example Type 021N, Thiothrix, S. natans, Type 1701, M. parvicella, Nocardioforms).
- Check DO in each zone and at different times of day, especially at peak load.
- Check nutrients, influent septicity, F/M and grease loading.
3Possible causes
- Low DO filaments: S. natans, Type 1701, H. hydrossis. Often from aeration limits or high load.
- Low F/M filaments: M. parvicella, Type 0041, Type 0675, Type 1851. Common in long SRT, completely mixed basins.
- Septic wastewater and sulfide: Thiothrix, Type 021N, Beggiatoa.
- Nutrient deficiency: Type 021N, Thiothrix, also viscous bulking.
- Grease and oil: Nocardioforms and M. parvicella, usually with foam.
4Next investigation
- Match the dominant filament to its probable cause and then check that condition in your data.
- Review DO logs at 15 minute resolution for low periods; daily averages hide them.
- Measure soluble ammonia and orthophosphate leaving the aeration basin.
5Corrective actions
- Correct the root cause: DO, nutrients, septicity, F/M gradient (selector), or grease control.
- Manage clarifiers with RAS while the cause is corrected. The state point tool helps set RAS.
- Selective RAS chlorination can knock back filaments extending outside the floc. Typical starting doses are 2 to 3 lb chlorine per 1,000 lb of MLSS inventory per day, applied where mixing is good, with close microscope checks. Stop when filaments retract.
- Hydrogen peroxide or polymer can also help in the short term.
- Expect recovery to take two to three SRTs after the cause is fixed.
6When to call for help
- You plan to start RAS chlorination: get help setting the dose and watch for nitrification loss and effluent turbidity.
- Filament type cannot be identified or several types are present.
- The plant has bulked repeatedly in the same season.
Make one change at a time, record it, and follow your plant procedures and permit. If you suspect a toxic discharge, a safety hazard or a permit violation, notify your supervisor right away.