How Much Air Does My Aeration Basin Need?

By Brad Musick, President, Wastewater Solutions, Inc. 1,323 words.

Aeration is usually the largest energy user at an activated sludge plant, often half or more of the plant's power bill. It is also the process variable most likely to cause trouble when it is short: low DO leads to filaments, poor nitrification and odors. So "how much air do I need?" is both a process question and a budget question.

This article walks through the calculation from oxygen demand to air flow, explains each factor in plain terms, and gives practical tips for delivering the right amount of air.

Step 1: How much oxygen do the bugs need?

Oxygen demand in an activated sludge basin comes from three things:

  1. BOD removal. Heterotrophic bacteria use oxygen to oxidize organic matter and for their own respiration. A typical range is 0.9 to 1.3 lb oxygen per lb BOD removed, depending on SRT (longer SRT, more oxygen). We use 1.1 here.
  2. Nitrification. About 4.57 lb oxygen per lb ammonia-N converted to nitrate.
  3. Denitrification credit. When nitrate is used instead of oxygen in an anoxic zone, it saves about 2.86 lb oxygen per lb nitrate-N denitrified.

The actual oxygen requirement (AOR) is:

AOR (lb/d) = 1.1 x BOD removed (lb/d) + 4.57 x NH3-N nitrified (lb/d) minus 2.86 x NO3-N denitrified (lb/d)

Worked example

White River WRRF (fictional) design: 8.0 MGD, aeration influent BOD 150 mg/L, effluent soluble BOD 5 mg/L, ammonia-N nitrified 30 mg/L, nitrate-N denitrified 20 mg/L.

BOD removed = 8.0 x (150 minus 5) x 8.34 = 9,674 lb/d. Times 1.1 = 10,642 lb/d O2

NH3-N nitrified = 8.0 x 30 x 8.34 = 2,002 lb/d. Times 4.57 = 9,148 lb/d O2

NO3-N denitrified = 8.0 x 20 x 8.34 = 1,334 lb/d. Times 2.86 = 3,816 lb/d O2 credit

AOR = 10,642 + 9,148 minus 3,816 = 15,973 lb/d

Nitrification is almost half the demand. That is typical, and it is why plants that start nitrifying often find their blowers suddenly too small. The plant's design value is 15,745 lb/d, close to this estimate; the small difference is in the assumptions.

Step 2: Convert field oxygen to standard oxygen

Diffusers are rated in clean water at standard conditions (20 C, sea level, zero DO). In mixed liquor, transfer is lower because of:

  • Alpha: contaminants (surfactants, grease) reduce transfer. Fine bubble diffusers often have alpha of 0.4 to 0.7.
  • Beta: dissolved salts reduce oxygen saturation slightly (about 0.95 to 0.99).
  • DO in the basin: the driving force is the difference between saturation and actual DO. Running 2 mg/L instead of 0.5 mg/L lowers the driving force.
  • Temperature and elevation: warm water and high altitude reduce saturation.
  • Fouling (F): diffusers foul over time.

These factors are combined into the AOR/SOR ratio. For fine bubble systems, 0.4 to 0.55 is common. White River uses 0.50.

SOR = AOR / (AOR/SOR ratio) = 15,745 / 0.50 = 31,490 lb/d

Step 3: Convert standard oxygen to air flow

Air at standard conditions contains about 0.0173 lb of oxygen per cubic foot (about 23% oxygen by weight at 0.075 lb/ft³). Only a fraction of that oxygen dissolves. That fraction is the standard oxygen transfer efficiency (SOTE). Fine bubble diffusers at 14 to 15 ft submergence might have SOTE of 25 to 35%. White River uses 29%.

Air (scfm) = SOR / (SOTE x 0.0173 x 1,440)

= 31,490 / (0.29 x 0.0173 x 1,440)

= 31,490 / 7.224 = 4,359 scfm

That matches the plant design average air of about 4,360 scfm. The oxygen requirement calculator does both steps.

Step 4: Check against what you have

White River has four 2,500 scfm blowers (three duty, one standby), for a firm capacity of 7,500 scfm. Design average is about 4,360 scfm and max day about 7,000 scfm. So on a peak day the plant needs nearly all its firm capacity. When Blower B-2 failed in September and only two blowers were available (5,000 scfm), DO dropped to about 1.0 mg/L, and low DO filaments started growing within days.

That is the practical lesson: compare your oxygen demand at peak with your firm blower capacity (largest blower out of service). If peak demand is above firm capacity, you are one bearing failure away from a DO problem.

Peak versus average

Oxygen demand varies through the day, often by a factor of 1.5 to 2 between night and the afternoon peak. Return streams such as centrate add a large ammonia load (and thus oxygen demand) when dewatering runs. Plan air capacity and DO control for the peaks, and schedule dewatering for low load periods when possible.

Mixing air

Diffused air systems also need a minimum air rate for mixing, typically on the order of 0.10 to 0.12 scfm per square foot of basin floor for fine bubble grids, or a minimum air flow per diffuser set by the manufacturer. At low load, mixing air may exceed oxygen demand and DO runs high. That is not waste if it is truly needed for mixing, but check whether you can lower the minimum or use mixers.

Delivering the right air: DO control

DO setpoints. Many plants run 1.5 to 2.0 mg/L in the first aerobic zone and lower toward the end. White River runs a tapered system: 2.0, 1.5 and 1.0 mg/L in grids 1 through 3. Each 1 mg/L of DO above what the process needs often costs 10 to 20% more air, because it lowers the driving force for transfer.

Most open valve control. Blower pressure is lowered until one grid valve is nearly fully open, which minimizes header pressure and energy.

Ammonia based aeration control (ABAC). An ammonia analyzer adjusts DO setpoints so air follows the nitrification load. It can save 10 to 20% of aeration energy and reduce overaeration at night.

Signs the air is wrong

  • Not enough: DO below setpoint at peak, ammonia bleed, low DO filaments, odors.
  • Too much: DO well above setpoint, pin floc, poor denitrification (DO carried into anoxic zones by recycle), high power use.
  • Poor transfer: more air for the same DO over months, rising blower pressure, boils. See poor oxygen transfer.

A quick field check: air per diffuser

Divide total air by the number of diffusers and compare with the manufacturer's range. White River has 3,600 nine inch membrane discs rated for about 0.5 to 2.5 scfm each. At 4,360 scfm the average is 4,360 / 3,600 = 1.21 scfm per diffuser, comfortably inside the range. But the grids are tapered (45, 33 and 22% of the air), so the rate per diffuser in each grid depends on how many diffusers it has and how its valve is set. Check each grid separately:

  • Below the minimum, diffusers may not open evenly, mixing suffers, and solids can settle on the floor.
  • Above the maximum, bubbles get larger, SOTE drops, and membranes wear faster.

If a grid is pinned at its minimum while DO runs high, the system is mixing limited, not oxygen limited. If a grid is at its maximum and DO is still low, the plant needs more diffusers or more blower capacity in that zone, not just a higher setpoint.

Summary

  1. AOR = BOD demand + nitrification demand minus denitrification credit.
  2. SOR = AOR divided by the field to standard ratio.
  3. Air = SOR / (SOTE x 0.0173 x 1,440).
  4. Compare peak demand with firm blower capacity.
  5. Use good DO control to deliver only what the process needs.